The short answer

A lighting schedule identifies every decorative and architectural fixture with the technical information needed to coordinate, price, order and install it: model, finish, lamp or integral source, colour temperature, output, voltage, dimming, mounting, control and drawing reference. It is the data companion to the reflected ceiling plan.

Download the CSVNo email, no account. Opens in Excel, Numbers or Google Sheets.

A symbol on a ceiling plan says where a light goes. The schedule says which light it is and whether it will work with the circuit, dimmer, ceiling construction and visual intent. Keeping those jobs separate makes the drawing readable without stripping out the information the electrician and purchaser need.

What each column carries

One row per fixture type and configuration. The same pendant in two finishes is two types because it produces two different orders.

ColumnWhat goes in itExample
TypeThe tag used on the reflected ceiling plan and elevations. Keep it short, stable and unique across the drawing set.L-07
Room / locationWhere the type occurs, including a more precise mounting location when several conditions share a room.Kitchen island
DescriptionPlain-language fixture category so the schedule remains readable before someone looks up the model.Linear pendant
Manufacturer / modelThe complete ordering identity, including size or configuration suffixes that change performance or mounting.A-N-D / Pipeline 40
FinishThe manufacturer's exact finish name and code, coordinated with adjacent hardware and the approved presentation.Aged brass AB-02
QtyTotal for this exact type and configuration, reconciled against every symbol on the drawing before issue.2
Source / lampLamp base and replacement lamp or integral LED module, including whether the source is supplied with the fixture.Integral LED, included
CCT / CRIColour temperature and colour rendering. A beautiful fixture with the wrong light quality is still the wrong fixture.2700K / 90+ CRI
Lumens / wattageOutput and connected load used for lighting calculations, circuit coordination and energy review.2800 lm / 32 W
VoltageLine voltage or driver requirement. Imported decorative fixtures frequently fail here unless checked before purchase.120 V
Dimming / controlProtocol and compatible control requirement, coordinated with the electrical and smart-home specifications.0–10 V, Lutron-compatible
Mounting / heightRecessed, surface, wall or suspended condition plus mounting height or drop where the drawings need a number.Suspended, bottom at 72 in AFF
RCP / detail refThe drawing and detail that locate or explain the installation, keeping the schedule connected to geometry.A6.02 / 5-A8.11
Lead time / statusCurrent quoted lead time and specification status, because fixtures often set rough-in and ceiling close dates.10 weeks / approved
NotesDriver location, remote transformer, blocking, wet-location rating or other coordination the standard fields cannot carry.Remote driver above accessible cabinet

Schedule and drawing must reconcile

  1. Count every type tag on the reflected ceiling plan and compare it with the quantity in the schedule.
  2. Coordinate mounting heights with elevations, millwork and ceiling details rather than leaving them only in product literature.
  3. Confirm dimming protocol, driver location and voltage with the electrical designer before the client deposit becomes a non-cancellable order.
  4. Issue the schedule with a revision date whenever a fixture changes, even if the symbol location stays the same.

Common questions

What is the difference between a lighting schedule and an RCP?
The reflected ceiling plan locates fixtures, switching, ceiling changes and other overhead elements. The lighting schedule identifies each fixture type and carries the ordering and technical data. The type tag is the link between them.
Should decorative lighting be in the FF&E schedule too?
It may appear in the FF&E schedule for client price, approval and purchasing, but the lighting schedule still carries the technical coordination fields. Use the same item or type reference so the two views stay connected.

More templates

Keep reading